SALE
NEW

New Original PLC DVP64EH00R3 DVP64EH00T3 DVP80EH00R3 DVP80EH00T3 DVP64EH00R2 In Boxed-in Brackets from Home Improvement

Scroll to product details, material & care and sizing

$ 375.50

Add to cart Add to wishlist

Term:
ethernet plc, dc pwm, plc screen, Wholesale fx3u plc, Wholesale plc wifi, Wholesale delta plc, Wholesale fx3u, Wholesale plc transistor, Wholesale xlogic, Wholesale plc program, Wholesale control plc, Wholesale fx1n,

New Original PLC DVP64EH00R3 DVP64EH00T3 DVP80EH00R3 DVP80EH00T3 DVP64EH00R2 In Boxed Details & Specification :

Item Specifications
Material Metal
DIY Supplies Electrical
Usage Industrial
Standard or Nonstandard Standard
Model Number DVP64EH00R3 DVP64EH00T3 DVP80EH00R3 DVP80EH00T3 DVP64EH00R2
is_customized Yes
Structure other

New Original PLC DVP64EH00R3 DVP64EH00T3 DVP80EH00R3 DVP80EH00T3 DVP64EH00R2 In Boxed 

023499ae12e2511088773c2c6cc9251e9f7b510d7068f9fafd2750ce19dfaa3c2f457f75b0f8fb372971e2e14ae01fad1f3bf0b8e3515c3fe27325fea48f0338

HTB1t9l_QVXXXXbvXFXXq6xXFXXXS

Features

EH2 series is well equipped with outstanding operational speed, large programming capacity and built in application and communication instructions, multiple special extension modules and function cards, enabling the efficiency of the MPU to be utilized to its fullness.

Specifications

*MPU points: 16 / 20 / 32 / 40 / 48 / 64 / 80 
*Max. I/O points: 512 
*Program capacity: 16K Steps 
*Instruction execution speed: 0.24µS (basic instruction) 
*Communication port: Built-in RS-232 and RS-485, compatible with MODBUS ASCII / RTU communication protocol 
*Data register: 10,000 words 
*File register: 10,000 words 
*High-speed pulse output: 
20-point and 32-point models support 2-point 200KHz pulse output (Y0, Y2); 40-point models support A/B phase 200KHz pulse output (Y0, Y1)(Y2, Y3) and 2-point 200KHz pulse output (Y4, Y6). 
*Built-in 4 groups of hardware high-speed counters

Standard

Hardware high-speed counter

1 phase 1

1 phase 1

1 phase 2

2 phase 2

group

bandwidth

group

bandwidth

group

bandwidth

group

bandwidth

6

10KHz

2/2

200KHz/20KHz

2/2

200KHz/20KHz

2/2

200KHz/20KHz

 

Model

Items

16EH

00_2

20EH

00_2

32EH

00_2

32EH

00_M2

40EH

00_2

48EH

00_2

60EH

00_2

64EH

00_2

80EH

00_2

Power supply

voltage

100 ~ 240VAC (-15% ~ 10%); 50/60Hz + - 5%

Fuse capacity

2A/250VAC

Power

consumption

50VA

60VA

80VA

DC24V current

output

500mA

Power supply

 

DC24V output short circuit 

Voltage

withstand

1,500VAC (Primary-secondary), 1,500VAC (Primary-PE),

500VAC (Secondary-PE)

Insulation

resistance

> 5M Ohm at 500VDC (between all I/O points and ground)

Noise immunity

ESD: 8KV Air Discharge

EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V

Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV, RS: 26MHz ~

1GHz, 10V/m

Grounding

The diameter of grounding wire shall not be less than that of L, N terminal of

the power supply. (When many PLCs are in use at the same time, please

make sure every PLC is properly grounded.)

Operation/

storage

Operation: 0 °C ~55 °C (temperature), 50~95% (humidity), pollution degree 2

Storage: -25 °C ~70 °C (temperature), 5~95% (humidity)

Vibration/shock

resistance

International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 &

IEC 68-2-27 (TEST Ea)

Weight (g)

R

500

520

652

644

710

748

742

836

948

T

480

500

612

644

675

688

742

756

848

 

Input Point

Spec

Items

Two Differential

inputs (200kHz)

24VDC single common port input

200kHz

20kHz

10kHz

Input wiring type

Independent

wiring

Change wiring from S/S to SINK or SOURCE

Input indicator

LED display; light on = ON, light off = OFF

Input voltage (+ - 10%)

5~24VDC

24VDC

Input point configuration

#1

#2

#3

#4

Input impedance

4.7K Ohm

4.7K Ohm

3.3K Ohm

4.7K Ohm

Active Level

Off à On

> 1mA (5V)

> 4mA (16.5V)

> 6mA (18.5V)

> 4mA (16.5V)

On à Off

< 0.4mA (2V)

< 1.5mA (8V)

< 2.2mA (8V)

< 1.5mA (8V)

Response time #5

Off à On

< 150ns

< 150ns

< 3.5us

< 8us

On à Off

< 3us

< 3us

< 20us

< 60us

#1: The frequency of differential input points X0, X1, X4, and X5 on DVP32EH00M2 is 200kHz.

#2: The frequency of input points X0, X1, X4, and X5 is 200kHz. The frequency of input points X10, X11, X14 and X15 on DVP40/60EH2 is 200kHz.

#3: The bandwidth of input points X10, X11, X14, and X15 is 20kHz (except for input points on DVP40/60EH2).

#4: The bandwidth of the input points other than the high-speed input points listed above is 10kHz.

#5: Input points X0 ~ X7and X10 ~ X17 can conduct 10 ~ 60ms digital filter adjustment.

Output Point

           Spec

 

Items

Two

differential

outputs

Single common port

transistor output

Single common port

relay output

Low speed

High speed

Max. frequency

200kHz

10kHz

200kHz

Load ON/OFF control

Output indicator

LED display; light on = ON, light off = OFF

Minimum load

/

2mA/DC power

Working voltage

5VDC

5 ~ 30VDC

< 250VAC, 30VDC

Insulation

Line Driver

Photo coupler isolation

Magnetic isolation

Maximum

load

Resistive

< 25mA

0.5A/1 point (4A/COM)

2A/1 point (5A/COM)

Inductive

/

12W (24VDC)

#1

Lamp

/

2W(24VDC)

20WDC/100WAC

Max. output response

time

0.2us

OffàOn: 20us

OnàOff: 30us

0.2us

10ms

#1: Life curves